MEASURED DIMENSIONS

Full length measurement of F.A.

Grill width measurements.

Deviations from vertical axis on every grid.

F.A. Twist determination with respect to the lower nozzle.

Upper nozzle inclination with respect the lower nozzle.

Gap between upper nozzle/lower nozzle and

SICOMDIM

®

Dimensional Characterization of PWR Fuel Assemblies

Measurement

Precission (mm)

Tilt

+_ 1.0

Length

+_ 0.5

Grid width

+_ 0.2

Bow

+_ 0.4

Twist

+_ 0.4

LEVEL

BENCH

FRAME

INSPECTION

MODULE

CALIBRATION BLOCK