Previous Page  4 / 6 Next Page
Basic version Information
Show Menu
Previous Page 4 / 6 Next Page
Page Background

SICOR

A system for inspection of revolution components

SPEAKING THE FACTORY LANGUAGE

Beyond conventional UT systems

1

With SICOR, Level III expert defines inspection plan based on

Profile definition

Ray tracings

2

SICOR computes ultrasonic parameters

3

Operator executes inspection for each part

4

SICOR automatically performs all checks and on-line adjustments

according to norm requirements

Measurement of sound speed

Automatic probe position check

Automatic calibration check and adjustment

Part profile

3D shape

Zone definition